® Xtra Test Strips measure glucose (sugar) in capillary whole blood outside of the body (in vitro diagnostic use) when used with the microdot Xtra Blood Glucose Test System. The measurement range of the microdot® System is 20 to 525 mg/dL. Proven to consistently deliver reliable results when it matters most. Range tested 45 to 472 mg/dL (2.5 to 26.2 mmol/L). Slope 0.973y-Intercept 3.96 mg/dL (0.22 mmol/L). This means that the microdot® system compared well to a laboratory method. Store the strips in their original vial in a cool, dry place between 50° and 86° F (10°-30° C). Keep away from sunlight and heat. Do not refrigerate or freeze. When you take a strip from the vial, close the cap immediately. Use the strip immediately. Do not use microdot® Test Strips more than 90 days after the vial is first opened. Write the discard date on the vial when you first open it.
Check the expiry date on the vial. If the expiry date has passed do not use the strips. Always code the meter for each new vial of strips according to the user manual. Take a strip from the vial and put it into the meter. Check that the black contact bars are facing the meter and the test zone and letters are facing up. Close the vial immediately. Push the strip in firmly until it stops. You will see the meter turn on automatically. The meter then checks each item of information on its display. You will then see the code number that the meter is using: "11" for example. Check that the code number on the screen and the code number printed on the vial are the same. If they are not the same, code the meter as instructed by the user manual. After the code number appears, the drop of blood symbol will appear and begin flashing. You can now apply the blood sample.
Take a strip from the vial and put it into the meter. Check that the black contact bars are facing the meter and GlycoModeBloodSugar.com the test zone and letters are facing up. Close the vial immediately. Wash your hands in warm, soapy water and dry well. Lance your skin with the microdot® lancing device. Squeeze gently until you get a rounded drop of blood. If the control result is within the acceptable range, check your test method and rememberingbaltimore.net repeat your glucose test with a new strip. After 10 seconds the meter will beep, your glucose result will be displayed on the meter display and then automatically stored in the meter memory. Turn the meter off by removing the strip by hand or ejecting it as described below. To eject the strip, hold the meter vertically above a safe disposal bin with the strip pointing into the bin and push the eject button. What Do Your Results Mean? Your blood glucose values will vary due to such things as diet, time of day and what you are doing.
Your healthcare professional will help you to understand these variations. You should set your own range of expected GlycoMode blood sugar support glucose values, testing times, and discuss your blood glucose results with your healthcare professional. The normal fasting adult blood glucose range for a non diabetic is 70-105 mg/dL (3.9 - 5.8 mmoI/L). Very high or very low blood glucose readings can indicate a serious medical condition. Repeat the test if you see an unusual reading. If these results are still unusual, or do not match your symptoms, contact your health care professional for advice. Hi or Lo readings may indicate hyper or hypoglycemia and should be treated immediately. A control solution is used to check the performance of the microdot® system and your test technique. Run a quality control check with microdot® Control Solution if your blood sugar result seems unusually high or low unlike your previous results, or is inconsistent with your symptoms.